pdpa specifications

The specific DANTEC Fiber PDA used at spray research, inc. has the following system level measurement range and accuracy:
·         Size
-          Range:      0.5 to 10,000 µm
-         Accuracy:   Typically 4% (depends on optical configuration)
-         Resolution:  Typically 9 bits
-         Dynamic Range: Typically 40:1 (depends on optical configuration)
·         Velocity
-         Maximum: 500 meters/sec (depends on optical configuration)
-         Accuracy: Typically ±1%
-         Resolution: Typically 8 bits
·         Concentration
-         Maximum:  Typically 1x106/cm3 (depends on optical configuration)
-         Accuracy:  Typically ±15% (depends on optical configuration)

  

back to DANTEC pdpa pdpa components

              


Sspray research . . . because nozzles are everywhere©