scanning rate-of-change patternator

Our proprietary scanning rate-of-change patternator was developed by spray research specifically to optimize the measurement of spray flux density distributions of the large, high-volume sprays produced by industrial-scale atomizers.

The instrument measures the rate-of-change of liquid collection into a single collector that is moved continuously through the spray envelope along a pre-programmed path with a known velocity profile. The scanning patternator allows accurate, rapid and flexible measurements of spray flux density distributions along any axis or linear [or curvi-linear] traverse of the spray envelope. The velocity profile of the traverse is under computer control, dynamically adjusting the local traverse velocity to maintain the collection rate within user-specified limits. By these means, the scanning patternator can accommodate dramatically uneven liquid distributions without loss of resolution.

By adjusting the ratio of effective aperture to collector volume, the scanning patternator can be used on sprays of widely diverse flow rates without loss of spatial resolution.

 

       
back to patternation pdpa patternator tube patternator  

Sspray research . . . because nozzles are everywhere©
Contact us by email at lab@sprayresearch.com  
Last modified: August 08, 2003